PULSe:DCYCle
This command sets the duty cycle of the triggered output pulse. The duty cycle
units are specified in percent.
Returned parameters <NR3>
PULSe:HOLD
This command specifies whether the pulse width or the duty cycle is to be held
constant when the pulse period changes. The following tables describe how the
duty cycle, period, and width are affected when one, two, or all three parameters
are set in a single program message.
Returned parameters <CRD>
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Command syntax [SOURce:]PULSe:DCYCle <Nrf+>
Parameters 0 to 100 (percent) | MINimum | MAXimum
*RST value 50
Examples
PULS:DCYC 75
Query syntax [SOURce:]PULSe:DCYCle?
Related commands PULS:COUN
Command syntax [SOURce:]PULSe:HOLD <parameter>
Parameters WIDTh | DCYCle
*RST value WIDTh
Examples
PULS:HOLD DCYC
Query syntax [SOURce:]PULSe:HOLD?
Related commands PULS:COUN
PULS:DCYC MAX
PULS:HOLD
PULS:PER
PULS:DCYC
PULS:PER
Language Dictionary
PULS:WIDT
PULS:WIDT
3
151