List:voltage:offset; List:voltage:offset:points - Keysight Technologies 6811C Programming Manual

Ac power solutions
Hide thumbs Also See for 6811C:
Table of Contents

Advertisement

LIST:VOLTage:OFFSet

This command specifies the DC offset points in a list. The offset points are given in
the command parameters, which are separated by commas. The order in which
the points are entered determines the sequence in which they are output when a
list is triggered. Changing list data while a subsystem is in list mode generates an
implied ABORt.
The maximum peak voltage that the ac source can output is 425 V
includes any combination of voltage, voltage offset, and function shape values.
Therefore, the maximum value that can be programmed depends on the
peak-to-rms ratio of the selected waveform. For a sine wave, the maximum
voltage that can be programmed is 300 V
Returned parameters <NR3>{, <NR3>}

LIST:VOLTage:OFFSet:POINts?

This query returns the number of points specified in LIST:VOLTage:OFFSet. Note
that it returns only the total number of points, not the point values.
Returned parameters <NR1>
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Command syntax [SOURce:]LIST:VOLTage:OFFSet <NRf+>{, <NRf+>}
Parameters –425 to +425 | MAXimum | MINimum
Unit V (DC voltage)
Examples
LIST:VOLT:OFFS 50, 75, 100
Query syntax [SOURce:]LIST:VOLTage:OFFSet?
Related commands LIST:VOLT:OFFS:POIN?
LIST:VOLT:SLEW
Query syntax [SOURce:]LIST:VOLTage:OFFSet:POINts?
Examples
LIST:VOLT:OFFS:POIN?
Related commands LIST:VOLT:OFFS
Language Dictionary
.
rms
LIST:COUN
LIST:DWEL
3
. This
peak
LIST:STEP