CALibrate:SECure:CODE

CALibration:SECure:CODE
This command can only be used in calibration mode. It allows you to change the
calibration password. A new password is automatically stored in non-volatile
memory and does not have to be stored with CALibrate:SAVE. If the password is
set to 0, password protection is removed and the ability to enter the calibration
mode is unrestricted. This setting is non-volatile; it will not be changed by power
cycling or *RST or SYSTem:PRESet.
Keysight Models 6811C, 6812C, and 6813C Programming Guide
Command syntax CALibrate:SECure:CODE <NRf>
CALibration:SECure:CODE <NRf>
Parameters 0 (default)
Examples
CAL:SEC:CODE 6813 | CAL:SEC:CODE 02.1997
Related commands CAL:PASS