4.4 Thermofuse Replacement
1. Remove the fusing unit. (Refer to "Fusing Unit Removal.")
2. Remove the fusing unit cover (3 screws).
3. Remove the pressure plate [A] (2 screws) and the thermofuse bracket [B] (1 screw).
4. Remove the thermofuse lead wire [C] from the metal wire clamp [D] (1 screw).
5. Replace the thermofuse (1 connector), and reassemble.
5-27
31 August 1989