4.7 No-Load Operation Test Run

4.7

No-Load Operation Test Run

◆ No-Load Operation Test Run
This section explains how to operate the drive with the motor decoupled from the load during a test run.
Before Starting the Motor
Check the following items before operation:
• Ensure the area around the motor is safe.
• Ensure external emergency stop circuitry is working properly and other safety precautions have been taken.
During Operation
Check the following items during operation:
• The motor should rotate smoothly (i.e., no abnormal noise or oscillation).
• The motor should accelerate and decelerate smoothly.
No-Load Operation Instructions
The following example illustrates a test run procedure using the digital operator.
Note: Before starting the motor, set the frequency reference d1-01 to 6 Hz.
1
Turn on the power to the drive. The initial display appears.
LO
Press the
key to select LOCAL.
2
RE
The LO/RE light will turn on.
Press
to give the drive a Run command.
RUN
3
RUN will light and the motor will rotate at 6 Hz.
Ensure the motor is rotating in the correct direction and that no faults or alarms
4
occur.
If there is no error in step 4, press
Increase the frequency in increments of 10 Hz, verifying smooth operation at all
5
speeds. For each frequency, check the drive output current using monitor U1-03.
The current should be well below the motor rated current.
Example: 6 Hz → 60 Hz
100
Operating Procedure
to increase the frequency reference.
LCD Display
- MODE -
FREF(OPR)
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.0A
JOG
FWD
DIGITAL OPERATOR JVOP-180
- MODE -
U1-01= 0.00Hz
U1-02= 0.00Hz
U1-03= 0.0A
JOG
F1
ESC
RESET
RUN
Off
DIGITAL OPERATOR JVOP-180
- MODE -
U1-01= 6.00Hz
U1-02= 0.00Hz
U1-03= 0.0A
JOG
F1
ESC
RESET
RUN
RUN
Off
Motor
YASKAWA ELECTRIC EZZ010928 FSDrive-MV1000 Instructions
DRV
Rdy
LSEQ
LREF
FWD/REV
ALARM
DRV
Rdy
FREF (OPR)
LSEQ
LREF
FWD
FWD/REV
F2
LO
RE
ENTER
STOP
On
ALARM
DRV
Rdy
FREF (OPR)
LSEQ
LREF
FWD
FWD/REV
F2
LO
RE
ENTER
STOP
RUN
On
Forward

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents