Toshiba e-STUDIO555 Service Manual page 286

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO555:
Table of Contents

Advertisement

Checking
Conditio
timing
n
During ready
1
2
During
1
printing
2
At Energy
1
Saving Mode
At paper jam
1
* The figures in the "Condition" field denote the priority of error checking.
* The figures in the "Error code" and "Counter" fields with parentheses denote that an error status
has not yet been determined (= error status is detected only once).
e-STUDIO555/655/755/855
FUSER UNIT
Temperature judged
Center
Rear
Front
thermist
thermist
thermist
or
or
240°C or
-
above
-
250°C or
above
-
-
270°C or
above
40°C or
-
below
-
40°C or
below
-
-
40°C or
below
-
-
240°C or
-
above
-
250°C or
above
-
-
270°C or
above
40°C or
-
below
-
40°C or
below
-
-
40°C or
below
-
-
240°C or
-
above
-
250°C or
above
-
-
270°C or
above
-
-
240°C or
-
above
-
250°C or
above
-
-
270°C or
above
-
-
13 - 12
Pressure
Error
roller
code
thermist
or
or
-
-
C449
-
-
-
-
-
C447
-
-
-
-
0°C or
C467
below
-
-
C449
-
-
-
-
-
C447
-
-
-
-
0°C or
C467
below
-
-
C449
-
-
-
-
250°C or
C468
above
-
-
C449
-
-
-
-
250°C or
C468
above
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
Error
Counter
judging
(08-400)
timing
23
On usual
7
25
On usual
24
27
On usual
26
29
On usual
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents