(6)
Take out the drum upward.
(7)
Remove 3 screws to take off the flange on
the front side.
(8)
Pull out the drum upward.
<<Precaution when installing the drum
•
Make sure that the gap plate is not caught
with the drum shaft.
•
Be sure to install the drum shaft and
cleaner frame without a gap.
•
No foreign matter must be attached on
the cleaner stay.
e-STUDIO555/655/755/855
DRUM/CLEANER UNIT
shaft>>
10 - 8
Fig. 10-9
Screw
Screw
Fig. 10-10
No gap
Fig. 10-11
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
Cleaner stay
Gap plate