[E] Temperature/humidity sensor (S7)
(1)
Take off the control panel unit.
(
P.5-12 "[A] Control panel unit")
(2)
Disconnect 1 connector, remove 1 screw,
and then take off the temperature/humidity
sensor.
[F] Exhaust duct
(1)
Take off the wire cleaner drive unit.
(
P.9-11 "[B] Wire cleaner drive unit / Wire
cleaner drive motor (M12)")
(2)
Pull out the transfer/transport unit.
(3)
Take off the left upper cover.
(
P.2-44 "[I] Left upper cover")
(4)
Open the left lower cover (exit cover).
(5)
Disconnect 3 connectors and release the
harness from 4 clamps.
(6)
Remove 1 screw, slide the exhaust duct to
the front side to release the hook, and then
pull it out toward you.
[G] Duct out fan (M27) / Exit section cooling fan (M29)
(1)
Take off the exhaust duct.
(
P.9-14 "[F] Exhaust duct")
(2)
Disconnect 1 connector and pull out the duct
out fan.
(3)
Disconnect 1 connector, remove 2 screws,
and then take off the exit section cooling fan
with the bracket.
(4)
Remove 2 screws and take off the exit
section cooling fan from the bracket.
e-STUDIO555/655/755/855
PROCESS RELATED SECTION
Screw
Connector
Duct out fan
© 2009 - 2011 TOSHIBA TEC CORPORATION All rights reserved
9 - 14
Temperature/humidity sensor
Fig. 9-21
Clamp
Connector
Screw
Exhoust duct
Fig. 9-22
Exit section cooling fan
Fig. 9-23