I/O Module Information - HPE 3PAR StoreServ 8000 Service And Upgrade Manual

Hide thumbs Also See for 3PAR StoreServ 8000:
Table of Contents

Advertisement

Item
6
Power cooling
module 1
7
Power connection
1

I/O module information

This information applies only to the I/O module for the HPE 3PAR StoreServ 8000 Storage system.
IMPORTANT: Notice that the I/O modules are installed differently between the SFF drive enclosure
and the LFF drive enclosure.
In the SFF drive enclosure, the I/O modules in the enclosure are inverted 180° from each other,
as well as the SAS ports.
In the LFF drive enclosure, the I/O modules in the enclosure are installed in the same direction,
as well as the SAS ports.
Figure 71: I/O module numbering, SFF drive enclosure rear view
Figure 72: I/O module numbering, LFF drive enclosure rear view
SAS ports
The I/O module has two SAS ports (DP-1 and DP-2) and each includes two LEDs.
102
More information
Description
The power cooling module (PCM) is an integrated power supply and cooling
fan. One PCM can supply enough power for the enclosure. Each PCM must
draw power from different mains. If one main fails, operation of the other PCM
continues.
This power connection requires a power cable to be attached between the
power supply and an independent electrical source capable of supporting the
entire power load of the enclosure and controlled by its own circuit breaker.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents