Cage - HPE 3PAR StoreServ 8000 Service And Upgrade Manual

Hide thumbs Also See for 3PAR StoreServ 8000:
Table of Contents

Advertisement

Cabling

cage7

cabling suggested action 1
Use the CLI showcage command to verify that both cages are available through two ports, before
replacing the cable specified in the error message.
cli% showcage cage6 cage7
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
6 cage6 0:1:1
7 cage7 0:1:1
cabling example 2
cli% checkhealth -detail cablingChecking cabling
Component --Summary Description--- Qty
Cabling
Wrong I/O module or port
--------------------------------------
1 total
Component -Identifier- ---------------------Detailed Description----------------------
Cabling
cage2
Cabling
cage2
--------------------------------------------------------------------------------------
2 total
root@jnodec103288:~# showcage cage2
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
2 cage2 0:1:2
cabling suggested action 2
For cables that must be moved to different ports in the same I/O Module: Use the CLI showcage
command to verify that the cage is available through two ports, before moving one or more cables to the
specified ports. For cables that must be moved between different I/O Modules and/or Drive Enclosures
(cages), contact the Hewlett Packard Enterprise Support Center to request support for changing the
cabling of your system. Moving cables on a running system can cause degraded PDs and LDs.
cli% showcage cage2
Id Name
LoopA Pos.A LoopB Pos.B Drives Temp
2 cage2 0:0:2
cage
Displays drive enclosure (cage) conditions that are not optimal and reports exceptions if any of the
following do not have normal states:
Ports
SFP signal levels (RX power low and TX failure)
Power supplies
Cage firmware (is not current)
Reports if a servicecage operation has been started and has not ended.
Cages are supported for hardware platform
Format of possible cage exception messages
Check connections or replace cable from (cage6, I/O 0, DP-2) to (cage7, I/O 0, DP-1) - links at 6Gbps
1 1:1:1
0
0 1:1:1
1
Cable in (cage2, I/O 0, DP-2) should be in (cage2, I/O 0, DP-1)
Cable in (cage2, I/O 0, DP-1) should be in (cage2, I/O 0, DP-2)
1 1:1:2
0
1 1:0:2
0
RevA RevB Model FormFactor
10 28-30 1.76 1.76 DCS8
10 27-30 1.76 1.76 DCS8
2
2
RevA RevB Model FormFactor
10 13-34 402e 402e DCS7
RevA RevB Model FormFactor
10 13-34 402e 402e DCS7
SFF
SFF
SFF
SFF
Troubleshooting
141

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents