HPE 3PAR StoreServ 8000 Service And Upgrade Manual page 154

Hide thumbs Also See for 3PAR StoreServ 8000:
Table of Contents

Advertisement

Checks for an Unknown sparing algorithm. For example, when it has not been set
Checks for drives experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
Reports if there are PDs that do not have entries in the firmware DB file
Reports PDs with slow SAS connections
Reports minimum number of PDs in a drive enclosure (cage) and behind a node pair
Reports PDs that are not admitted to the system
Format of possible pd exception messages
PD disk:<pdid> "Degraded States: <showpd -s -degraded>"
PD disk:<pdid> "Failed States: <showpd -s -failed">
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD File: <filename> "Folder not found on all Nodes in <folder>"
PD File: <filename> "Folder not found on some Nodes in <folder>"
PD File: <filename> "File not found on all Nodes in <folder>"
PD File: <filename> "File not found on some Nodes in <folder>"
PD Disk:<pdID> "<pdmodel> PD for cage type <cagetype> in cage position <pos> is missing from firmware database"
PD Cage:<cageID> "There must be at least 1 PD with primary path to Node:<nodeID>"
PD Cage:<cageID> "PDs <class/rpm/cap> unbalanced. Primary path: <p_count> on Node:<nodeID>, <c_count> on Node:<nodeID>"
PD Nodes:<nodelist> "Only <count> <class/rpm/cap> PDs are attached to these nodes; the minimum is <MINDISKCNT>"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> on both ports"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> from port <0|1>"
PD disk:<pdWWN> "Unadmitted PD in cage position <CagePos> Type <devType>"
PD cage:<cageID>,mag:<magID> "Magazine has a failed servicemag operation"
PD cage:<cageID>,mag:<magID> "Magazine is being serviced"
PD cage:<cageID>,mag:<magID> "Magazine has an active servicemag operation in progress"
pd example 1
Component -------------------Summary Description------------------- Qty
PD
PDs that are degraded or failed
Component -Identifier- ---------------Detailed Description-----------------
PD
disk:48
PD
disk:49
...
PD
disk:107
pd suggested action 1
Both degraded and failed drives show up in this report. When an FC path to a drive Enclosure (cage) is
not working, all drives in the cage have a state of Degraded due to the nonredundant condition. Use
commands such as showpd, showpd -s, showcage, showcage -d.
cli% showpd -degraded -failed
Id CagePos Type Speed(K) State
48 3:0:0
FC
49 3:1:0
FC
...
107 4:9:3
FC
cli% showpd -s -degraded -failed
cli% showcage -d cage3
pd example 2
cli% checkhealth -detail pdChecking pd
Component -------------------Summary Description------------------- Qty
PD
Unbalanced PD types in cages
PD
PDs that a degraded
------------------------------------------------------------------------
2 total
154
Troubleshooting
Detailed State: missing_B_port,loop_failure
Detailed State: missing_B_port,loop_failure
Detailed State: failed,notready,missing_A_port
Total
10 degraded
139520
10 degraded
139520
15 failed
428800
----Size(MB)---- ----Ports----
Free A
B
115200 2:0:2* -----
121344 2:0:2* -----
0 -----
3:0:1*
1
1
2
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents