Checks for an Unknown sparing algorithm. For example, when it has not been set
•
Checks for drives experiencing a high number of IOPS
•
Reports if a servicemag operation is outstanding (servicemag status)
•
Reports if there are PDs that do not have entries in the firmware DB file
•
Reports PDs with slow SAS connections
•
Reports minimum number of PDs in a drive enclosure (cage) and behind a node pair
•
Reports PDs that are not admitted to the system
Format of possible pd exception messages
PD disk:<pdid> "Degraded States: <showpd -s -degraded>"
PD disk:<pdid> "Failed States: <showpd -s -failed">
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD File: <filename> "Folder not found on all Nodes in <folder>"
PD File: <filename> "Folder not found on some Nodes in <folder>"
PD File: <filename> "File not found on all Nodes in <folder>"
PD File: <filename> "File not found on some Nodes in <folder>"
PD Disk:<pdID> "<pdmodel> PD for cage type <cagetype> in cage position <pos> is missing from firmware database"
PD Cage:<cageID> "There must be at least 1 PD with primary path to Node:<nodeID>"
PD Cage:<cageID> "PDs <class/rpm/cap> unbalanced. Primary path: <p_count> on Node:<nodeID>, <c_count> on Node:<nodeID>"
PD Nodes:<nodelist> "Only <count> <class/rpm/cap> PDs are attached to these nodes; the minimum is <MINDISKCNT>"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> on both ports"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> from port <0|1>"
PD disk:<pdWWN> "Unadmitted PD in cage position <CagePos> Type <devType>"
PD cage:<cageID>,mag:<magID> "Magazine has a failed servicemag operation"
PD cage:<cageID>,mag:<magID> "Magazine is being serviced"
PD cage:<cageID>,mag:<magID> "Magazine has an active servicemag operation in progress"
pd example 1
Component -------------------Summary Description------------------- Qty
PD
PDs that are degraded or failed
Component -Identifier- ---------------Detailed Description-----------------
PD
disk:48
PD
disk:49
...
PD
disk:107
pd suggested action 1
Both degraded and failed drives show up in this report. When an FC path to a drive Enclosure (cage) is
not working, all drives in the cage have a state of Degraded due to the nonredundant condition. Use
commands such as showpd, showpd -s, showcage, showcage -d.
cli% showpd -degraded -failed
Id CagePos Type Speed(K) State
48 3:0:0
FC
49 3:1:0
FC
...
107 4:9:3
FC
cli% showpd -s -degraded -failed
cli% showcage -d cage3
pd example 2
cli% checkhealth -detail pdChecking pd
Component -------------------Summary Description------------------- Qty
PD
Unbalanced PD types in cages
PD
PDs that a degraded
------------------------------------------------------------------------
2 total
154
Troubleshooting
Detailed State: missing_B_port,loop_failure
Detailed State: missing_B_port,loop_failure
Detailed State: failed,notready,missing_A_port
Total
10 degraded
139520
10 degraded
139520
15 failed
428800
----Size(MB)---- ----Ports----
Free A
B
115200 2:0:2* -----
121344 2:0:2* -----
0 -----
3:0:1*
1
1
2
40