Power Cooling Module Leds, Alternating-Current, Drive Enclosure - HPE 3PAR StoreServ 8000 Service And Upgrade Manual

Hide thumbs Also See for 3PAR StoreServ 8000:
Table of Contents

Advertisement

Table 33: 764W PCM LEDs, alternating-current, controller node enclosure rear
view
LED
Function
AC input fail
PCM OK
Fan fail
DC output fail
Battery fail
Battery good

Power cooling module LEDs, alternating-current, drive enclosure

This information applies only to the HPE 3PAR 580W power cooling module for the HPE 3PAR StoreServ
8000 Storage system.
NOTE: Labels on the PCM for the drive enclosure show the model as 580W PCM Gold Series.
Figure 106: 580W PCM LEDs, alternating-current, drive enclosure rear view
Status
State
Amber solid
No AC power or PCM fault
Amber flashing
Green solid
AC present and PCM On / OK
Green flashing
Standby mode
Amber solid
PCM fail or PCM fault
Amber flashing
Firmware download
Amber solid
Amber flashing
Firmware download
Amber solid
Hard fault (not recoverable)
Amber flashing
Soft fault (recoverable)
Green solid
Present and charged
Green flashing
Charging or disarmed
Firmware Download
Locate active
No AC power
Fault
Out of tolerance
More information