Fbwc Module - HPE D2220sb Maintenance And Service Manual

Storage blade
Table of Contents

Advertisement

Disconnect the FBWC capacitor pack cable from the system board, and then remove the component.
5.
CAUTION: Be sure to wind the cable counterclockwise and to seat the cable firmly in the
connector. Otherwise, the cable may become disconnected and data may be lost.
To replace the component, reverse the removal procedure.

FBWC module

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION: Do not operate the D2220sb with the access panel open or removed. Operating
the D2220sb in this manner results in improper airflow and improper cooling that can lead to
thermal damage.
To remove the component:
Back up all data on the D2220sb.
1.
Power down the partner server blade (on page 20).
2.
Remove the D2220sb (on page 20).
3.
Remove the access panel (on page 25).
4.
Removal and replacement procedures 29

Advertisement

Table of Contents
loading