14. Verify that the replacement AC PCM has been successfully installed.
Confirm that the PCM OK LED is solid green and the battery good LED is solid green.
15. From the Service Console interface, verify that the State of the component and the storage system
are Normal (green).
16. After the component replacement, initiate Check Health on the storage system.
a. From the Service Console interface, select Systems.
b. Select Actions > Check health.
17. If significant time is left in the maintenance window, end the Maintenance Mode.
a. From the Service Console interface, select Systems.
b. Select Actions > Set maintenance mode.
c. To end the maintenance window associated with the replacement, click X.
The flow of support information and local notifications of system alerts will be sent to Hewlett
Packard Enterprise again.
18. Follow the return instructions provided with the replacement component.
Replacing an alternating-current power cooling module in a drive enclosure
—SP 5.x
This procedure is for the replacement of an alternating-current power cooling module (AC PCM) in a drive
enclosure using HPE 3PAR Service Processor (SP) 5.x.
IMPORTANT:
Only one power cooling module can be serviced at a time. If another power cooling module is to
be serviced, verify that the first serviced power cooling module is healthy and functioning, and
then restart this servicing procedure from the beginning for the next power cooling module to be
serviced.
To prevent overheating, the replacement of the power cooling module requires a maximum
service time of six minutes.
Ensure that cables are clear of the power cooling module when installing.
Prerequisites
Order a replacement component by contacting your Hewlett Packard Enterprise authorized service
provider.
Procedure
Preparation
1.
Unpack the component and place on an ESD safe mat.
2.
Connect to the service processor in the Service Console interface:
Browse to the IP address: https://<sp_ip_address>:8443
3.
Log in to the HPE 3PAR SP and enter the admin account credentials.
Service