Outputs Of Valve Locations; Additional Outputs - Festo VIFB-02 Series Manual

Valve terminal/valve sensor terminal with field bus connection
Hide thumbs Also See for VIFB-02 Series:
Table of Contents

Advertisement

VIFB8 – 02
PNP outputs
(0,5A/24V)
Fig. 4/27: Additional outputs on valve sensor terminal
4-42
4. Installation

Outputs of valve locations

The outputs for the valves correspond to the
valve solenoid coils. They can only be used in
the intended form.
In general the following applies:
Outputs are not short-circuit protected
Two outputs per valve location
With unilaterally-operated valves the output
with the even bit number is used. The other
output cannot be used for other purposes.

Additional outputs

There are two additional outputs (O0.00 and
O0.01) on the valve-sensor coupling unit of the
valve sensor terminal. These additional outputs
are transistor outputs with positive logic (PNP
outputs).
9706