Chapter 9: Configuring Member Switches

Configuring a Member Switch - Part I

Step
1
Power on the member switch and wait two minutes for it to initialize the management
software. Refer to "Powering On a Switch" on page 138.
2
Start a local management session. Refer to "Starting a Local Management Session"
on page 141.
3
Enter the ENABLE command to move from the User Exec mode to the Privileged
Exec mode.
awplus> enable
4
Verify that the switch hardware is operating correctly, with the SHOW SYSTEM
ENVIRONMENT command. All components should have a status of Ok.
awplus# show system environment
Environment Monitoring Status
Overall Status: Normal
Resource ID: 1 Name: PSU Bay A (AT-PWR600)
ID Sensor (Units)
1
Device Present
2
Fan/Temperature Fault
.
158
The instructions for configuring a member switch are divided into two
parts. In Part I you do the following:
Display the hardware status with the SHOW SYSTEM
ENVIRONMENT command.
Display the firmware version number with the SHOW VERSION
command.
Enable VCStack with the STACK ENABLE command.
Set the switch ID number with the STACK RENUMBER command.
Add other member switches with the SWITCH PROVISION
command.
Save the configuration and reboot the switch with the WRITE and
REBOOT commands.
Allied Telesis recommends filling out the worksheet in "Stack Worksheet"
on page 73 before performing the procedures.
To configure a member switch, perform the procedure in Table 28.
Table 28. Configuring a Member Switch - Part I
Description and Command
Reading
Low Limit
Yes
-
Yes
-
High Limit
Status
-
Ok
-
Ok

Advertisement

Table of Contents
loading