Configuring The Master Switch - Part I; Table 16: Configuring The Master Switch For 5Gbps Stacking Ports - Part I - Allied Telesis x530DP Series Installation Manual

Stackable gigabit layer 3+ ethernet switches alliedware plus v5.5.1-2.1
Table of Contents

Advertisement

Chapter 9: Building the Stack Trunk with 5Gbps Multi-Speed Ports
Configuring the
Master Switch -
Part I
Table 16. Configuring the Master Switch for 5Gbps Stacking Ports - Part I
Step
1
Power on the master switch and wait two minutes for it to initialize the management
software. Refer to Chapter 9, "Building the Trunk with Default 10 Gbps Stacking
Ports" on page 129.
2
Start a local management session. Refer to "Starting a Local Management Session"
on page 136.
3
Move to the Privileged Exec mode with the ENABLE command.
awplus> enable
Steps 4 to 6 display the status of the switch hardware and the version number of the
AlliedWare Plus management software.
134
6. Designate the 5Gbps ports as the stack trunk on the master switch,
with the STACKPORT command.
7. Save the changes with the WRITE command in the Privileged Exec
mode.
Here are the general steps to Part II:
1. Add the member switches as provisioned units to the master switch,
with the SWITCH PROVISION command. This step is to ensure that
the master switch knows about the member switches during the first
power-on of the stack.
2. Remove the stacking function from the default stacking ports 51 and
52 on the provisioned member switches with the NO STACKPORT
command.
3. Designate the 5Gbps ports as the stack trunk on the provisioned
member switches, with the STACKPORT command.
4. Save your changes with the WRITE command in the Privilege Exec
mode.
5. Reboot the switch with the REBOOT command.
6. Start a new local management session.
7. Verify the changes with the SHOW STACK and SHOW RUNNING-
CONFIG command.
To configure the master switch to use 5Gbps ports for the stack trunk,
perform the procedure in Table 16.
Description and Command

Advertisement

Table of Contents
loading

This manual is also suitable for:

X530dp-28ghxmX530dp-52ghxm

Table of Contents