Chapter 8: Configuring the Master Switch

Configuring the Master Switch - Part II

Step
1
Start a new local management session. Refer to "Starting a Local Management
Session" on page 141.
2
Move to the Privileged Exec mode with the ENABLE command.
awplus> enable
3
Move to the Global Configuration mode with the CONFIGURE TERMINAL command.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Steps 4 designates the types of transceivers to be used in ports 25, 29, 33, and 37 on the
master switch. The ports support 40Gbps QSFP+ transceivers, 100Gbps QSFP28
transceivers, and 40Gbps to 10Gbps breakout cables. The default is 40Gbps QSFP+
transceivers.
4
Designate the types of transceivers to be used in ports 25, 29, 33, and 37 on the
master switch with the PLATFORM PORTMODE INTERFACE command in the
Global Configuration mode. You can skip this step for ports that will be using 40Gbps
QSFP+ transceivers because that is the default setting. You can also skip this step
and configure the ports later if you are not using 100Gbps transceivers for the stack
trunk. For more information, refer to "Ports 25 to 37" on page 26 and "PLATFORM
PORTMODE INTERFACE" on page 134.
This example configures ports 33 and 37 for 100Gbps transceivers on the master
switch:
awplus(config)# platform portmode interface port1.0.33-1.0.37 100g
Steps 5 to 7 designate the stack ports on the master switch with the STACKPORT command.
5
Enter the port Interface modes of the ports that will be the stack trunk on the master
switch. This example assumes the master switch will use ports 33 and 37 as the stack
trunk. Be sure to modify the command to specify the ports for your stack trunk.
awplus(config)# interface port1.0.33-1.0.37
148
This section contains Part II for configuring the master switch. In this
procedure you do the following:
Designate the types of transceivers to be used in the ports 25, 29,
33, and 37 on the master and provisioned member switches.
Designate the trunk ports.
To perform Part II, perform the procedure in Table 26.
Table 26. Configuring the Master Switch- Part II