Configuring A Member Switch - Part I; Table 16: Configuring A Member Switch - Part I - Allied Telesis AT-SBx908 Installation Manual

Table of Contents

Advertisement

Configuring a
Member Switch -
Part I
Step
1
Power on a member switch and wait two minutes while it initializes the management
software:
- If the switch has AC power supplies, refer to "Powering On AT-SBxPWRSYS2 AC
Power Supplies" on page 144.
- If the switch has the AT-SBxPWRSYS1-80 DC Power Supply, power on the DC
circuit and the On/Off switch on the power supply. For instructions on wiring the DC
connector, refer to Chapter 5, "Wiring the AT-SBxPWRSYS1-80 DC Power Supply"
on page 109.
2
Start a local management session. Refer to "Starting a Local Management Session"
on page 147.
2. Assign the member switch a priority number equal to its ID number,
with the STACK PRIORITY command in the Global Configuration
mode.
3. Designate the ports of the stack trunk for the member switch, with the
STACKPORT command in the port Interface mode.
4. Designate the ports of the stack trunk for the provisioned master
switch (ID 1), with the STACKPORT command in the port Interface
mode.
5. Save your changes with the WRITE command in the Privilege Exec
mode.
6. Restart the switch with the REBOOT command.
7. Start a new local management session.
8. Verify the changes with the SHOW STACK DETAIL command.
The instructions for configuring a member switch are divided into two
parts. Part I has you do the following:
View the hardware status and management software version
number.
Enable VCStack.
Set the switch ID number.
To configure a member switch, perform the procedure in Table 16.
Table 16. Configuring a Member Switch - Part I
Description and Command
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
157