Verifying the Master Switch

Step
1
Start a new local management session.
2
Move to the Privileged Exec mode with the ENABLE command.
awplus> enable
3
Enter the SHOW STACK command. Here is an example for a stack of four switches:
awplus# show stack
Virtual Chassis Stacking summary information
ID Pending ID
1
-
2
-
3
-
4
-
Operational Status
Stack MAC address
4
Verify the display for the following:
- The table should have one entry for the master switch (ID 1).
- The table should have one entry for each provisioned member switch (IDs 2 to 4). If
the table is missing a member switch, repeat the SWITCH PROVISION command in
"Configuring the Master Switch - Part I" on page 145.
- The master switch should have the priority 1. If the priority number is incorrect,
repeat the STACK PRIORITY command in "Configuring the Master Switch - Part I"
on page 145.
- The Operational Status should be Standalone Unit, indicating that stacking is
enabled and that the unit is operating as a stack of one switch. If the status is
Stacking Hardware Disabled, the stacking feature is disabled and needs to be
enabled. Repeat the STACK ENABLE command in "Configuring the Master Switch -
Part I" on page 145.
- Always remember to perform the WRITE command to save your configuration
changes.
Perform the steps in Table 27 to confirm the configuration of the master
switch.
Table 27. Verifying the Master Switch
Description and Command
MAC address
e01a.ba56.c208
-
-
-
x950 Series Installation Guide for VCStack
Priority
Status
1
Ready
-
-
-
-
-
-
Standalone unit
0000.ab56.d4a8 (Virtual MAC)
Role
Active Master
Provisioned
Provisioned
Provisioned
151