Step
1
Power on the member switch and wait two minutes for it to initialize the management
software. Refer to "Powering On a Switch" on page 124.
2
Start a local management session on the switch. Refer to "Starting a Local
Management Session" on page 127.
3
Enter the ENABLE command to move from the User Exec mode to the Privileged
Exec mode.
awplus> enable
9. Specify the types of transceivers to be used in slots 25, 29, 33, and 37
for both the provisioned master switch and member switch with the
PLATFORM PORTMODE INTERFACE command.
10. Designate the ports of the stack trunk on both the provisioned master
switch and member switch, with the STACKPORT command in the
port Interface mode.
11. Save your changes with the WRITE command in the Privilege Exec
mode.
12. Restart the switch with the REBOOT command.
13. Start a new local management session.
14. Verify the changes with the SHOW STACK and SHOW RUNNING-
CONFIG command.
The instructions for configuring the member switch are divided into two
parts. In Part I you do the following:
Display the hardware status.
Enable VCStack.
Set the switch ID number to 2.
To configure the member switch, perform the procedure in Table 18.
Table 18. Configuring the Member Switch - Part I
Description and Command