pvlan <range_list>
pvlan
Private VLAN
<range_list>
Default:
None
Usage Guide:
To create PVLAN ID for specific interface
Example:
To create PVLAN ID (5) for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # pvlan 5
pvlan isolation
Command:
pvlan isolation
pvlan
Private VLAN
isolation
Port isolation
Default:
None
Usage Guide:
To enable PVLAN isolation for specific interface
Example:
To enable PVLAN isolation for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # pvlan isolation
qos cos
Command:
qos cos <Cos : 0-7>
qos
Quality of Service
cos
Class of service configuration
<Cos : 0-7>
Default:
0
Usage Guide:
To configure CoS of QoS for specific interface
Example:
To configure CoS (4) of QoS for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
NS4750-24S-4T-4X-V2 Managed Switch Command Guide