Usage Guide:
To create a profile and configure the Sub ERPS interface port 0, port 1.
Example 1:
To create a profile 3 and configure the Sub ERPS interface port
0(GigabitEthernet 1/5), port 1(GigabitEthernet 1/6) without interconnected
mode and Major RIng group and virtual-channel
Switch# configure terminal
Switch (config)# erps 3 sub port0 interface GigabitEthernet 1/5
port1 interface GigabitEthernet 1/6
Example 2:
To create a profile 2 and configure the Sub ERPS interface port
0(GigabitEthernet 1/3), port 1(GigabitEthernet 1/4) with interconnected mode
and Major RIng group 1 and virtual-channel
Switch# configure terminal
Switch (config)# erps 1 sub port0 interface GigabitEthernet 1/3
interconnect 1 virtual-channel
erps <1-64> topology-change propagate
Command:
erps <1-64> topology-change propagate
<1-64>
ERPS group number
topology-change
propagate
Propagate
Default:
N/A
Usage Guide:
To configure topology change notification (TCN) propagation for the specific
profile.
Example:
To configure topology change notification (TCN) propagation for the specific
profile 1
Switch# configure terminal
Switch (config)# erps 1 topology-change propagate
erps <1-64> topology-change propagate
Command:
erps <1-64> version 1 | 2
<1-64>
ERPS group number
version
Default:
V2
NS4750-24S-4T-4X-V2 Managed Switch Command Guide
Topology Change
Version
Chapter 4: Commands for CLI configuration
45

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NS4750-24S-4T-4X-V2 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents