Cascade Controller - Danfoss VLT AQUA Drive FC 200 Operating Instructions Manual

Low harmonic drive
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

VLT AQUA Low Harmonic Drive Operating In-
structions

6.4.21 Cascade Controller 25-**

Par.
Parameter description
No. #
25-0* System Settings
25-00
Cascade Controller
25-02
Motor Start
25-04
Pump Cycling
25-05
Fixed Lead Pump
25-06
Number of Pumps
25-2* Bandwidth Settings
25-20
Staging Bandwidth
25-21
Override Bandwidth
25-22
Fixed Speed Bandwidth
25-23
SBW Staging Delay
25-24
SBW Destaging Delay
25-25
OBW Time
25-26
Destage At No-Flow
25-27
Stage Function
25-28
Stage Function Time
25-29
Destage Function
25-30
Destage Function Time
25-4* Staging Settings
25-40
Ramp Down Delay
25-41
Ramp Up Delay
25-42
Staging Threshold
25-43
Destaging Threshold
25-44
Staging Speed [RPM]
25-45
Staging Speed [Hz]
25-46
Destaging Speed [RPM]
25-47
Destaging Speed [Hz]
25-5* Alternation Settings
25-50
Lead Pump Alternation
25-51
Alternation Event
25-52
Alternation Time Interval
25-53
Alternation Timer Value
25-54
Alternation Predefined Time
25-55
Alternate if Load < 50%
25-56
Staging Mode at Alternation
25-58
Run Next Pump Delay
25-59
Run on Mains Delay
Default value
null
[0] Direct on Line
null
null
2 N/A
SR
100 %
casco_staging_bandwidth
(P2520)
15 s
15 s
10 s
[0] Disabled
null
15 s
null
15 s
10.0 s
2.0 s
SR
SR
0 RPM
0.0 Hz
0 RPM
0.0 Hz
null
[0] External
24 h
0 N/A
SR
[1] Enabled
[0] Slow
0.1 s
0.5 s
®
MG.20.T1.02 - VLT
is a registered Danfoss trademark
6 How to Programme the Low Harmonic Drive
4-set-up
Change dur-
ing operation
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
2 set-ups
FALSE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint8
0
Uint16
0
Uint16
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
0
Uint16
6
-1
Uint16
-1
Uint16
0
Uint8
0
Uint8
67
Uint16
-1
Uint16
67
Uint16
-1
Uint16
-
Uint8
-
Uint8
74
Uint16
VisStr[7
0
]
TimeOf-
DayWo-
0
Date
-
Uint8
-
Uint8
-1
Uint16
-1
Uint16
141

Advertisement

Table of Contents
loading

Table of Contents