7.10.2 Setting the operating pressure

NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 183) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Fig. 94: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1.
Pull the pressure controller (1) up.
2.
Turn the pressure controller until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure controller (1) down.
Operating Instructions 550-12-33/34 - 00.0 - 08/2017
(2) - Pressure gage