Servicing The Pneumatic System; Setting The Operating Pressure - DURKOPP ADLER 911-211 Service Instructions Manual

Hide thumbs Also See for 911-211:
Table of Contents

Advertisement

Maintenance

8.3 Servicing the pneumatic system

8.3.1 Setting the operating pressure

Proper setting
Refer to the Technical data ( p. 168) chapter for the permissible
operating pressure. The operating pressure cannot deviate by more than
± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 119: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1. Pull the pressure controller (1) up.
2. Turn the pressure controller until the pressure gage (2) indicates the
3. Push the pressure controller (1) down.
Service Instructions 911-211 - 02.0 - 10/2016
NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.
proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
(2) - Pressure gage
152

Advertisement

Table of Contents
loading

Table of Contents