Code Type
Possible causes
2177 Error
Stepper motor
overload (I²T)
2178 Error
Encoder error
2179 Error
Current sensor:
• Stepper motor card
• Control defective
2180 Error
Direction of rotation
2181 Error
Error in the reference
run
2182 Error
Stepper motor
current error
2183 Error
Stepper motor
overcurrent
2184 Error
Software error
2185 Error
Stepper motor
insulation error
defective
Remedial action
• Remove the cause of the
stiff movement or
blockage
• Replace step motor
• Replace control
• Check the connection of
the encoder cable and
replace, if necessary
• Replace control
• Replace control
• Replace encoder
• Check plug assignment
and change, if necessary
• Check wiring in machine
distributor and change it,
if necessary
• Test stepper motor phases
and check for correct
value
• Replace reference switch
• Remove blockage
• Check the encoder cable
and replace, if necessary
• Replace step motor
• Replace sewing motor
cable
• Replace step motor
• Replace control
• Perform reset
• Perform a software update
• Contact Customer Service
• Check motor phase and
PE for low-impedance
connection
• Replace encoder
• Replace step motor
167