DURKOPP ADLER 550-12-33 Operating Instructions Manual page 166

Table of Contents

Advertisement

164
Code Type
Possible causes
1056 Error
Sewing motor
overtemperature:
• Sewing motor not
• Sewing motor
• Control defective
1058 Error
Sewing motor speed
greater than setpoint:
• Reference switch
• Sewing motor
1060 Error
PowerParts
1061 Error
Sewing motor
disturbance:
• Encoder defective
• Sewing motor
1062 Error
Sewing motor
disturbance (IDMA
auto increment)
1120 Error
Software error:
• Parameter not
1203 Information Sewing motor:
Position not reached
1302 Error
Sewing motor current
error:
• Sewing motor
• Encoder cable not
• Encoder defective
Operating Instructions 550-12-33/34 - 00.0 - 08/2017
moving freely
defective
defective
defective
defective
initialized
blocked
connected or
defective
Troubleshooting
Remedial action
• Eliminate sluggishness
• Replace sewing motor
• Replace control
• Replace reference switch
• Replace sewing motor
• Replace control
• Switch off and on the
machine
• Replace encoder
• Replace sewing motor
• Contact customer service
• Switch off and on the
machine
• Perform a software update
• Switch off and on the
machine
• Perform a software update
• Contact Customer Service
• Remove the blockage
• Check the encoder cable
and replace, if necessary
• Replace sewing motor

Advertisement

Table of Contents
loading

This manual is also suitable for:

550-12-34

Table of Contents