Servicing The Pneumatic System; Setting Operating Pressure - DURKOPP ADLER 610-10 Operating Instructions Manual

Hide thumbs Also See for 610-10:
Table of Contents

Advertisement

Maintenance
Operating Instructions 610-10/630-10 - 01.0 - 01/2021
Proper setting
The oil level must always be between the minimum level mark (3)
and the maximum level mark (4) with the machine head tilted back
halfway.
Refilling oil
If necessary, fill oil through the filler opening as follows:
1.
Tilt the machine head ( p. 38).
2.
Loosen the screw plug (1) on the filler opening.
3.
Add oil up to but not past the maximum level marking (4).
4.
Tighten the screw plug (1).
5.
Erect the machine head again.
6.3

Servicing the pneumatic system

6.3.1

Setting operating pressure

NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 109) chapter for the permissi-
ble operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Check the operating pressure on a daily basis: You can read the
operating pressure on the pressure gage (2).