Servicing The Pneumatic System; Setting The Operating Pressure - DURKOPP ADLER 171 Operating Instructions Manual

Hide thumbs Also See for 171:
Table of Contents

Advertisement

66
6.3

Servicing the pneumatic system

6.3.1

Setting the operating pressure

NOTICE
Property damage from incorrect setting!
Incorrect operating pressure can result in damage to the
machine.
Ensure that the machine is only used when the operating
pressure is set correctly.
Proper setting
Refer to the Technical data ( p. 99) chapter for the permissible
operating pressure. The operating pressure cannot deviate by
more than ± 0.5 bar.
Check the operating pressure on a daily basis.
Fig. 35: Setting the operating pressure
(1) - Pressure controller
To set the operating pressure:
1.
Pull the pressure controller (1) up.
(2) - Pressure gage
Operating Instructions 171/173 - 02.0 - 09/2019
Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

173

Table of Contents