YOKOGAWA WT5000 User Manual page 83

Precision power analyzer, communication interface
Hide thumbs Also See for WT5000:
Table of Contents

Advertisement

5.11 INPut Group
[:INPut]:CURRent:RANGe[:ALL]
Function
Collectively sets the electric current range of all
elements.
[:INPut]:CURRent:RANGe[:ALL] {<Current>|
Syntax
(EXTernal,<Voltage>)}
760901 (30A High Accuracy Element)
• When the crest factor is set to 3:
<Current> = 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A,
<Voltage> = 50 mV, 100 mV, 200 mV, 500 mV,
• When the crest factor is set to 6 or 6A:
<Current> = 250 mA, 500 mA, 1 A, 2.5 A, 5 A,
<Voltage> = 25 mV, 50 mV, 100 mV, 250 mV,
760902 (5A High Accuracy Element)
• When the crest factor is set to 3:
<Current> = 5 mA, 10 mA, 20 mA, 50 mA,
<Voltage> = 50 mV, 100 mV, 200 mV, 500 mV,
• When the crest factor is set to 6 or 6A:
<Current> = 2.5 mA, 5 mA, 10 mA, 25 mA,
<Voltage> = 25 mV, 50 mV, 100 mV, 250 mV,
Example
:INPUT:CURRENT:RANGE:ALL 5A
:INPUT:CURRENT:RANGE:
ALL EXTERNAL,10V
[:INPut]:CURRent:RANGe:ELEMent<x>
Function
Sets or queries the electric current range of the
specified element.
[:INPut]:CURRent:RANGe:
Syntax
ELEMent<x> {<Current>|(EXTernal,
<Voltage>)}
[:INPut]:CURRent:RANGe:ELEMent<x>?
<x> = 1 to 7 (element)
<Current>, <Voltage> = See [:INPut]:CURRent:
RANGe[:ALL]
:INPUT:CURRENT:RANGE:ELEMENT1 5A
Example
:INPUT:CURRENT:RANGE:ELEMENT1?
-> :INPUT:CURRENT:RANGE:
ELEMENT1 5.0E+00
:INPUT:CURRENT:RANGE:
ELEMENT1 EXTERNAL,10V
:INPUT:CURRENT:RANGE:ELEMENT1?
-> :INPUT:CURRENT:RANGE:
ELEMENT1 EXTERNAL,10.00E+00
5-50
30 A (for direct current input)
1 V, 2 V, 5 V, 10 V (for external
current sensor input)
10 A, 15 A (for direct current input)
500 mV, 1 V, 2.5 V, 5 V (for
external current sensor input)
100 mA, 200 mA, 500 mA, 1 A,
2 A, 5 A (for direct current input)
1 V, 2 V, 5 V, 10 V (for external
current sensor input)
50 mA, 100 mA, 250 mA, 500 mA,
1 A, 2.5 A (for direct current input)
500 mV, 1 V, 2.5 V, 5 V (for
external current sensor input)
[:INPut]:CURRent:RANGe:{SIGMA|SIGMB|
SIGMC}
Function
Collectively sets the electric current range of all
the elements that belong to the specified wiring
unit (ΣA, ΣB, or ΣC).
Syntax
[:INPut]:CURRent:RANGe:{SIGMA|SIGMB|
SIGMC} {<Current>|(EXTernal,
<Voltage>)}
<Current>, <Voltage> = See [:INPut]:CURRent:
RANGe[:ALL]
Example
:INPUT:CURRENT:RANGE:SIGMA 5A
:INPUT:CURRENT:RANGE:
SIGMA EXTERNAL,10V
Description SIGMA, SIGMB, or SIGMC is invalid if the wiring
system setting ([:INPut]:WIRing) is made in such
a way that the corresponding wiring unit (ΣA, ΣB,
or ΣC) does not exist.
[:INPut]:CURRent:SRATio?
Function
Queries the external current sensor conversion
ratios of all elements.
[:INPut]:CURRent:SRATio?
Syntax
[:INPut]:CURRent:SRATio[:ALL]
Function
Collectively sets the external current sensor
conversion ratios of all elements.
[:INPut]:CURRent:SRATio[:ALL] {<NRf>}
Syntax
<NRf> = 0.0001 to 99999.9999
:INPUT:CURRENT:SRATIO:ALL 10
Example
[:INPut]:CURRent:SRATio:ELEMent<x>
Function
Sets or queries the external current sensor
conversion ratio of the specified element.
[:INPut]:CURRent:SRATio:
Syntax
ELEMent<x> {<NRf>}
[:INPut]:CURRent:SRATio:
ELEMent<x>?
<x> = 1 to 7 (element)
<NRf> = 0.0001 to 99999.9999
:INPUT:CURRENT:SRATIO:ELEMENT1 10
Example
:INPUT:CURRENT:SRATIO:ELEMENT1?
-> :INPUT:CURRENT:SRATIO:
ELEMENT1 10.0000
[:INPut]:CURRent:SRATio:{SIGMA|SIGMB
|SIGMC}
Function
Collectively sets the external current sensor
conversion ratios of all the elements that belong
to the specified wiring unit (ΣA, ΣB, or ΣC).
[:INPut]:CURRent:SRATio:
Syntax
{SIGMA|SIGMB|SIGMC} {<NRf>}
<NRf> = 0.0001 to 99999.9999
:INPUT:CURRENT:SRATIO:SIGMA 10
Example
Description SIGMA, SIGMB, or SIGMC is invalid if the wiring
system setting ([:INPut]:WIRing) is made in such
a way that the corresponding wiring unit (ΣA, ΣB,
or ΣC) does not exist.
IM WT5000-17EN