5.6 DISPlay Group
:DISPlay:TRENd<x>:ITEM<x>?
Function
Queries all settings for the specified trend.
:DISPlay:TRENd<x>:ITEM<x>?
Syntax
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of ITEM<x> = 1 to 16 (item number)
:DISPlay:TRENd<x>:ITEM<x>[:FUNCtion]
Function
Sets or queries the function, element, and
harmonic order of the specified trend item.
:DISPlay:TRENd<x>:
Syntax
ITEM<x>[:FUNCtion] {<Function>,
<Element>[,<Order>]}
:DISPlay:TRENd<x>:ITEM<x>:FUNCtion?
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of ITEM<x> = 1 to 16 (item number)
<Function> = {URMS|IRMS|P|S|Q|...}
<Element> = {<NRf>|SIGMa|SIGMB|SIGMC}
(<NRf> = 1 to 7)
<Order> = {TOTal|DC|<NRf>} (<NRf> = 1 to 500)
:DISPLAY:TREND1:ITEM1:
Example
FUNCTION URMS,1
:DISPLAY:TREND1:ITEM1:FUNCTION?
-> :DISPLAY:TREND1:ITEM1:
FUNCTION URMS,1
:DISPLAY:TREND1:ITEM1:
FUNCTION UK,1,1
:DISPLAY:TREND1:ITEM1:FUNCTION?
-> :DISPLAY:TREND1:ITEM1:
FUNCTION UK,1,1
Description • The trend item applies to the entire trend
display group. The <x> of TRENd<x> has no
meaning in the setting or query.
• For details on the <Function> options,
see "Numeric data functions" in "Function
Option List (Settings That Can Be Used for
<Function>)" at the end of the this group on
page 5-36 .
• If <Element> is omitted, the element is set to 1.
• If <Order> is omitted, the order is set to TOTal.
• <Element> and <Order> are omitted from
responses to functions that do not need them.
• In the case of a motor function (<Function>
= {SPEed|TORQue|SYNCsp|SLIP|PM}), the
<Element> section becomes <Motor>. <Order>
is not necessary.
<Motor> = 1 to 4 (motor number. Motor 1 when
omitted.)
5-32
:DISPlay:TRENd<x>:ITEM<x>:SCALing?
Function
Queries all scaling settings for the specified trend.
:DISPlay:TRENd<x>:ITEM<x>:SCALing?
Syntax
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of ITEM<x> = 1 to 16 (item number)
:DISPlay:TRENd<x>:ITEM<x>:SCALing:MO
DE
Function
Sets or queries the scaling mode of the specified
trend.
Syntax
:DISPlay:TRENd<x>:ITEM<x>:SCALing:
MODE {AUTO|MANual}
:DISPlay:TRENd<x>:ITEM<x>:SCALing:
MODE?
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of ITEM<x> = 1 to 16 (item number)
:DISPLAY:TREND1:ITEM1:SCALING:
Example
MODE AUTO
:DISPLAY:TREND1:ITEM1:SCALING:
MODE?
-> :DISPLAY:TREND1:ITEM1:SCALING:
MODE AUTO
:DISPlay:TRENd<x>:ITEM<x>:SCALing:VA
Lue
Function
Sets or queries the upper and lower limits of the
manual scaling of the specified trend.
:DISPlay:TRENd<x>:ITEM<x>:SCALing:
Syntax
VALue {<NRf>,<NRf>}
:DISPlay:TRENd<x>:ITEM<x>:SCALing:
VALue?
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of ITEM<x> = 1 to 16 (item number)
<NRf> = -9.999E+12 to 9.999E+12
:DISPLAY:TREND1:ITEM1:SCALING:
Example
VALUE 100,-100
:DISPLAY:TREND1:ITEM1:SCALING:
VALUE?
-> :DISPLAY:TREND1:ITEM1:SCALING:
VALUE 100.0E+00,-100.0E+00
Description • Set the upper limit and then the lower limit.
• This command is valid when the scaling mode
of the trend (:DISPlay:TRENd<x>:ITEM<x>:
SCALing:MODE) is set to MANual.
:DISPlay:TRENd<x>:T<x>
Function
Sets or queries the on/off status of the specified
trend.
:DISPlay:TRENd<x>:T<x> {<Boolean>}
Syntax
:DISPlay:TRENd<x>:T<x>?
<x> of TRENd<x> = 1 to 4 (trend display group)
<x> of T<x> = 1 to 16 (item number)
:DISPLAY:TREND1:T1 ON
Example
:DISPLAY:TREND1:T1?
-> :DISPLAY:TREND1:T1 1