5.6 DISPlay Group
:DISPlay:WAVE<x>?
Function
Queries all waveform display settings.
:DISPlay:WAVE<x>?
Syntax
<x> = 1 to 4 (waveform display group)
:DISPlay:WAVE<x>:ALL
Function
Collectively sets the on/off status of all waveform
displays.
:DISPlay:WAVE<x>:ALL {<Boolean>}
Syntax
<x> = 1 to 4 (waveform display group)
Example
:DISPLAY:WAVE1:ALL ON
:DISPlay:WAVE<x>:FORMat
Function
Sets or queries the display format of all
waveforms.
Syntax
:DISPlay:WAVE<x>:FORMat {SINGle|
DUAL|TRIad|QUAD|HEXa}
:DISPlay:WAVE<x>:FORMat?
<x> = 1 to 4 (waveform display group)
:DISPLAY:WAVE1:FORMAT SINGLE
Example
:DISPLAY:WAVE1:FORMAT?
-> :DISPLAY:WAVE1:FORMAT SINGLE
:DISPlay:WAVE<x>:GRATicule
Function
Sets or queries the graticule (grid) type.
Syntax
:DISPlay:WAVE<x>:GRATicule {GRID|
FRAMe|CROSshair}
:DISPlay:WAVE<x>:GRATicule?
<x> = 1 to 4 (waveform display group)
:DISPLAY:WAVE1:GRATICULE GRID
Example
:DISPLAY:WAVE1:GRATICULE?
-> :DISPLAY:WAVE1:GRATICULE GRID
Description This setting applies to the entire waveform display
group. The <x> of WAVE<x> has no meaning in
the setting or query.
:DISPlay:WAVE<x>:INTerpolate
Function
Sets or queries the waveform interpolation
method.
:DISPlay:WAVE<x>:INTerpolate {OFF|
Syntax
LINE}
:DISPlay:WAVE<x>:INTerpolate?
<x> = 1 to 4 (waveform display group)
:DISPLAY:WAVE1:INTERPOLATE LINE
Example
:DISPLAY:WAVE1:INTERPOLATE?
-> :DISPLAY:WAVE1:INTERPOLATE LINE
Description This setting applies to the entire waveform display
group. The <x> of WAVE<x> has no meaning in
the setting or query.
5-34
:DISPlay:WAVE<x>:POSition?
Function
Queries all waveform vertical position (center
position level) settings.
:DISPlay:WAVE<x>:POSition?
Syntax
<x> = 1 to 4 (waveform display group)
:DISPlay:WAVE:POSition:{U<x>|I<x>}
Function
Sets or queries the vertical position (center
position level) of the specified element's voltage
or current waveform.
Syntax
:DISPlay:WAVE:POSition:{U<x>|
I<x>} {<NRf>}
:DISPlay:WAVE:POSition:{U<x>|I<x>}?
<x> of WAVE<x> = 1 to 4 (waveform display group)
<x> of U<x>, I<x> = 1 to 7 (element)
<NRf> = -130.000 to 130.000 (%)
:DISPLAY:WAVE1:POSITION:U1 0
Example
:DISPLAY:WAVE1:POSITION:U1?
-> :DISPLAY:WAVE1:POSITION:U1 0.000
:DISPlay:WAVE<x>:POSition:{UALL|IA
LL}
Function
Collectively sets the vertical positions (center
position levels) of the voltage or current
waveforms of all elements.
Syntax
:DISPlay:WAVE<x>:POSition:{UALL|
IALL} {<NRf>}
<x> = 1 to 4 (waveform display group)
<NRf> = -130.000 to 130.000 (%)
:DISPLAY:WAVE1:POSITION:UALL 0
Example
:DISPlay:WAVE<x>:SVALue
Function
Sets or queries the on/off status of the scale
value display.
:DISPlay:WAVE<x>:SVALue {<Boolean>}
Syntax
:DISPlay:WAVE<x>:SVALue?
<x> = 1 to 4 (waveform display group)
:DISPLAY:WAVE1:SVALUE ON
Example
:DISPLAY:WAVE1:SVALUE?
-> :DISPLAY:WAVE1:SVALUE 1
Description This setting applies to the entire waveform display
group. The <x> of WAVE<x> has no meaning in
the setting or query.
IM WT5000-17EN