4.12 Main Menu - Data Readouts - Group 16

4.12.1 16-0* General Status
16-00 Control Word
Range:
Function:
0
[0 - 65535 ] View the Control word sent from the frequency
*
converter via the serial communication port in
hex code.
Bit number
15 14
13
12
11
10
9
Bit Bit = 0
00 Preset reference choice lsb
01 Preset reference choice second bit of
preset references
02 DC brake
03 Coasting
04 Quick-stop
05 Freeze output
06 Ramp stop
07 No function
08 No function
09 Ramp 1
10 Data not valid
11 Relay_A not active
12 Relay_B not active
13 Choice of Setup lsb
14 No function
15 No function
Table 4.7 Control Word
16-01 Reference [Unit]
Range:
0 ReferenceFeed-
[-4999 - 4999
backUnit
ReferenceFeed-
*
backUnit]
16-02 Reference [%]
Range:
Function:
0 %
[-200 - 200 %] View the total reference. The total
*
reference is the sum of digital, analog,
preset, bus, and freeze references.
16-03 Status Word
Range:
Function:
0
[0 - 65535 ] View the Status word sent from the frequency
*
converter via the serial communication port in
hex code.
®
VLT
DriveMotor FCP 106 and FCM 106 Programming Guide
8
7
6
5 4 3 2 1 0
Bit = 1
Ramp
Enable
Ramp
Ramp
Start
Reset
Jog
Ramp 2
Valid
Relay_A activated
Relay_B activated
No function
Reversing
Function:
View the present reference
value applied on impulse
or analog basis in the unit
resulting from the configu-
ration selected in
parameter 1-00 Configu-
ration Mode (Hz).
MG03N102 - Rev. 2013-12-02
Bit number
15
14
13
12
11
10
9 8 7 6 5 4 3 2 1 0
Bit
Bit = 0
00
Control not ready
01
VLT not ready
02
Coasting
03
No fault
04
No warning
05
Reserved
06
No trip lock
07
No warning
08
Speed ≠ ref.
09
Local control
10
Out of range
11
Not running
12
No function
13
Voltage OK
14
Current OK
15
Temperature OK
Table 4.8 Status Word
16-05 Main Actual Value [%]
Range:
Function:
0 %
[-200 - 200 %] View the 2-byte word sent with the Status
*
word to the bus Master reporting the
Main Actual Value.
16-09 Custom Readout
Range:
0 CustomRea-
[0 - 9999
doutUnit
CustomRea-
*
doutUnit]
4.12.2 16-1* Motor Status
16-10 Power [kW]
Range:
Function:
0 kW
[0 - 1000
Displays DC link power in kW. The value
*
kW]
shown is calculated on the basis of the
actual motor voltage and motor current.
16-11 Power [hp]
Range:
Function:
0 hp
[0 - 1000
View the DC link power in hp. The value
*
hp]
shown is calculated on the basis of the
actual motor voltage and motor current.
Bit = 1
Ready
Ready
Enable
Trip
Warning
Trip lock
Warning
Speed = ref.
Bus control
Frequency OK
Running
No function
Above limit
Above limit
Above limit
Function:
View the user-defined readouts
as defined in
parameter 0-30 Custom Readout
Unit, parameter 0-31 Custom
Readout Min Value and
parameter 0-32 Custom Readout
Max Value. Custom Readout
81