Parameters
4-41 Warning Frequency High
Range:
4
4
4.5.3 4-5* Adj. Warnings
Define adjustable warning limits for current. Warnings are
shown on the display, programmed output or serial bus.
4-50 Warning Current Low
Range:
0 A
[ 0 - 194.0
*
A]
4-51 Warning Current High
Range:
Size
[ 0.0 -
related
194.0 A]
*
4-54 Warning Reference Low
Range:
-4999
[ -4999 -
*
4999 ]
4-55 Warning Reference High
Range:
4999.000
[Depend on
*
the value of
4-54 Warning
Reference Low-
4999.000]
4-56 Warning Feedback Low
Range:
-4999.000
[-4999.000-
*
Depend on the
value of 4-57
50
VLT
Function:
Status Word. Output Relay can be
configured to indicate this warning.
LCP warning light does not light
when this parameter set limit is
reached.
Function:
Enter the I
value. When the motor current
LOW
falls below this limit, a bit in the statusword is
set. This value can also be programmed to
produce a signal on the digital output or the
relay output.
Function:
Enter the I
value. When the motor
HIGH
current exceeds this limit, a bit in the
statusword is set. This value can also be
programmed to produce a signal on the
digital output or the relay output.
Function:
Enter the lower reference limit. When the
actual reference falls below this limit, the
display reads Ref
. The signal outputs
LOW
can be programmed to produce a status
signal on terminal 27 or 29 and on relay
output 01 or 02.
Function:
Use this parameter to set a higher
limit for the reference range.
When the actual reference exceeds
this limit, the display reads
Reference High. Warning bit 19 is set
in 16-94 Ext. Status Word. Output
Relay can be configured to indicate
this warning. LCP warning light does
not light when this parameter set
limit is reached.
Function:
Use this parameter to set a lower
limit for the feedback range.
®
DriveMotor FCP 106 and FCM 106 Programming Guide
4-56 Warning Feedback Low
Range:
4-57 Warning Feedback High
Range:
4999.000
*
the value of
4-56 Warning
Feedback Low
-4999.000]
4-58 Missing Motor Phase Function
Option: Function:
NOTICE
This parameter cannot be adjusted while the
motor is running. Missing Motor Phase
Function is always disabled with PM.
Select On, to display an alarm in the event of a
missing motor phase. Select Off, for no missing motor
phase alarm. However the On setting is strongly
recommended to avoid motor damage.
[0]
Off No alarm is displayed if a missing motor phase occurs.
[1]
On
An alarm is displayed if a missing motor phase occurs.
*
4.5.4 4-6* Speed Bypass
Define the Speed Bypass areas for the ramps. Some
systems call for avoiding certain output frequencies or
speeds, due to resonance problems in the system. 3
frequency ranges can be avoided.
4-61 Bypass Speed From [Hz]
Range:
0 Hz
[ 0 - 500
*
Hz]
MG03N102 - Rev. 2013-12-02
Function:
Warning
When the feedback falls below this
Feedback High]
limit, the display reads Feedback
Low. Warning bit 6 is set in 16-94
Ext. Status Word. Output Relay can
be configured to indicate this
warning. LCP warning light does
not light when this parameter set
limit is reached.
Function:
[Depend on
Use this parameter to set a higher
limit for the feedback range.
When the feedback exceeds this
limit, the display reads Feedback
High. Warning bit 5 is set in 16-94
Ext. Status Word. Output Relay can
be configured to indicate this
warning. LCP warning light does
not light when this parameter set
limit is reached.
Function:
Some systems call for avoiding certain
output speeds due to resonance problems
in the system. Enter the lower limits of the
speeds to be avoided.