0-37 Display Text 1
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
0-38 Display Text 2
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
0-39 Display Text 3
Range:
Function:
[0 - 0 ] In this parameter it is possible to write an individual
text string to be read via serial communication.
Only used when running BACnet.
4.1.4 0-4* LCP
Enable, disable and password protect individual keys on
the LCP.
0-40 [Hand on] Key on LCP
Option:
Function:
[0]
Disabled Select [0] Disabled to avoid accidental start of the
frequency converter in Hand Mode.
[1]
Enabled [Hand On] is enabled.
*
0-42 [Auto on] Key on LCP
Option:
Function:
[0]
Disabled Select [0] Disabled to avoid accidental start of the
frequency converter from LCP.
[1]
Enabled [Auto On] is enabled.
*
0-44 [Off/Reset] Key on LCP
Option:
[0]
Disabled
[1]
Enabled
*
[7]
Enable Reset Only
4.1.5 0-5* Copy/Save
Copy parameter settings between set-ups and to/from the
LCP.
0-50 LCP Copy
Option:
Function:
[0]
No copy
*
[1]
All to LCP
Copies all parameters in all set-ups from the
frequency converter memory to the LCP
memory. For service purposes it is
®
VLT
DriveMotor FCP 106 and FCM 106 Programming Guide
0-50 LCP Copy
Option:
[2]
All from
LCP
[3]
Size indep.
from LCP
0-51 Set-up Copy
Option:
[0]
No copy
*
[1]
Copy from
setup 1
[2]
Copy from
setup 2
[9]
Copy from
Factory setup
4.1.6 0-6* Password
0-60 Main Menu Password
Range:
0
[0 - 999 ] Define the password for access to the Main Menu
*
Function:
MG03N102 - Rev. 2013-12-02
Function:
recommended to copy all parameters to the
LCP after commissioning.
Copies all parameters in all set-ups from the
LCP memory to the frequency converter
memory.
Copies only the parameters that are
independent of the motor size. The latter
selection can be used to programme several
frequency converters with the same function
without disturbing motor data which are
already set.
Function:
No function
Copy from setup 1 to setup 2.
Copy from setup 2 to setup 1.
Copy factory setting to programming setup
(selected in parameter 0-11 Programming
Set-up).
Function:
via the [Main Menu] key. Setting value to 0
disables the password-function.
4