Parameter Lists
Par. No. # Parameter description
1-25
Motor Nominal Speed
1-26
Motor Cont. Rated Torque
1-29
Automatic Motor Adaption (AMA)
1-3* Adv. Motor Data
1-30
Stator Resistance (Rs)
1-33
Stator Leakage Reactance (X1)
1-35
Main Reactance (Xh)
1-37
d-axis Inductance (Ld)
1-39
Motor Poles
1-4* Adv. Motor Data II
1-40
Back EMF at 1000 RPM
1-5* Load Indep. Setting
1-50
Motor Magnetisation at Zero Speed
1-52
Min Speed Normal Magnetising [Hz]
1-55
U/f Characteristic - U
1-56
U/f Characteristic - F
1-6* Load Depen. Setting
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-66
Min. Current at Low Speed
1-7* Start Adjustments
1-71
Start Delay
1-72
Start Function
1-73
Flying Start
1-8* Stop Adjustments
1-80
Function at Stop
1-82
Min Speed for Function at Stop [Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-93
Thermistor Source

6.1.4 2-** Brakes

Par. No. # Parameter description
2-0* DC-Brake
2-00
DC Hold/Motor Preheat Current
2-01
DC Brake Current
2-02
DC Braking Time
2-04
DC Brake Cut In Speed
2-06
Parking Current
2-07
Parking Time
2-1* Brake Energy Funct.
2-10
Brake Function
2-16
AC Brake, Max current
2-17
Over-voltage Control
®
VLT
DriveMotor FCP 106 and FCM 106 Programming Guide
Default value
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
4 N/A
ExpressionLimit
100 %
0 Hz
ExpressionLimit
ExpressionLimit
0 %
0.1 s
100 %
0.005 s
50 %
0 s
[2] Coast/delay time
[0] Disabled
[0] Coast
0 Hz
ExpressionLimit
[0] None
Default value
50 %
50 %
10 s
0 Hz
100 %
3 s
[0] Off
100 %
[2] Enabled
MG03N102 - Rev. 2013-12-02
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Type
67
Uint16
-1
Uint32
-
Uint8
-3
Uint32
-3
Uint32
-2
Uint32
-3
Int32
0
Uint8
0
Uint16
6
0
Uint16
-1
Uint16
-1
Uint16
-1
Uint16
0
Int16
-2
Uint16
0
Uint16
-3
Uint16
0
Uint32
-1
Uint8
-
Uint8
-
Uint8
-
Uint8
-1
Uint16
-
Uint8
-
Uint8
Type
0
Uint16
0
Uint16
-1
Uint16
-1
Uint16
0
Uint16
-1
Uint16
-
Uint8
-1
Uint16
-
Uint8
101
6

Advertisement

Table of Contents
loading