https://g4t8660g.houston.hpe.com (15.241.136.80)
https://s79t0166g.sgp.ext.hpe.com (15.211.158.65)
https://s79t0165g.sgp.ext.hpe.com (15.211.158.66)
https://g9t6659g.houston.hpe.com (15.241.48.100)
HPE StoreFront Remote Servers:
https://sfrm-production-llb-austin1.itcs.hpe.com (16.252.64.51)
https://sfrm-production-llb-houston9.itcs.hpe.com (16.250.64.99)
For communication between the Service Processor and the HPE 3PAR StoreServ Storage system, the
customer network must allow access to the following ports on the storage system.
Port 22 (SSH)
Port 5781 (Event Monitor)
Port 5783 (CLI)
For communication between the browser and the Service Processor, the customer network must allow
access to port 8443 on the SP.

Connection methods for the SP

Use one of the following methods to establish a connection to the HPE 3PAR Service Processor (SP).
Web browser connection—Use a standard web browser and browse to the SP.
With SP 4.x: https://<hostname> or https://<sp_ip_address>
With SP 5.x: https://<sp_ip_address>:8443
Secure Shell (SSH) connection—Use a terminal emulator application to establish a Secure Shell
(SSH) session connection from a host, laptop, or other computer connected on the same network, and
then connect to the HPE 3PAR Service Processor (SP) IP address or hostname.
Laptop connection—Connect the laptop to the physical SP with an Ethernet connection (LAN).
IMPORTANT:
If firewall permissive mode for the HPE 3PAR SP is disabled, you must add firewall rules to allow
access to port 8443 or add the hosts to the firewall. By default, permissive mode is enabled for the
firewall. To add rules using the HPE 3PAR SC interface (SP 5.x) or HPE 3PAR SPOCC interface
(SP 4.x), you must first enable permissive mode through the HPE 3PAR TUI interface (SP 5.x) or
HPE 3PAR SPMaint interface (SP 4.x). After adding the rules, you can then use the interface to
disable permissive mode again.