cli% showport -sfp -ddm 0:1:1 1:1:1
--------------Port 0:1:1 DDM--------------
--Type-- Units Reading Low
Temp
C
29
Voltage
mV
3339
TX Bias
mA
8
TX Power uW
478
RX Power uW
522
--------------Port 1:1:1 DDM--------------
--Type-- Units Reading Low
Temp
C
33
Voltage
mV
3332
TX Bias
mA
7
TX Power uW
476
RX Power uW
98
port Example 2
Component -Summary Description- Qty
Port
Missing SFPs
Component -Identifier- -Detailed Description--
Port
port:0:3:1
port Suggested Action 2
FC node-ports that normally contain SFPs will report an error if the SFP has been removed. The condition
can be checked using the showport -sfp command. In this example, the SFP in 1:1:1 has been
removed from the Adapter:
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:1:1 OK
HP-F
0:1:2 OK
HP-F
1:1:1 -
-
1:1:2 OK
HP-F
port Example 3
cli% checkhealth -detail port
port Suggested Action 3
Check the state of the port with showport. If a port is offline, it was deliberately put in that state using the
controlport offline command. Offline ports might be restored using controlport rst.
-Warning- --Alarm--
High Low
High
-5
85
-10
90
3000 3600 2900 3700
2
14
1
17
158
562
125
631
15
1000 10
1258
-Warning- --Alarm--
High Low
High
-5
85
-10
90
3000 3600 2900 3700
2
14
1
17
158
562
125
631
15
1000 10
1258
1
SFP is missing
8.5 No
8.5 No
8.5 No
No
No
- -
-
No
No
Yes
Yes
Yes
-
-
Yes
Yes