Pdch - HPE 3PAR StoreServ 7000 Storage Service And Upgrade Manual

Customer edition
Hide thumbs Also See for 3PAR StoreServ 7000 Storage:
Table of Contents

Advertisement

cli% showpd -s 3
Id CagePos Type -State-- -Detailed_State- --SedState
3 0:3:0
------------------------------------------------------
1 total
cli% showpd -i 3
cli% showfirmwaredb
pd Example 5
Component --Identifier-- -------Detailed Description----------
PD
--
pd Suggested Action 5
Check the system's Sparing Algorithm value using the CLI command showsys -param . The value is
normally set during the initial installation (OOTB). If it must be set later, use the command setsys
SparingAlgorithm ; valid values are Default, Minimal, Maximal, and Custom. After setting the
parameter, use the admithw command to programmatically create and distribute the spare chunklets.
cli% showsys -param
System parameters from configured settings
----Parameter-----
RawSpaceAlertFC
RawSpaceAlertNL
RawSpaceAlertSSD
RemoteSyslog
RemoteSyslogHost
SparingAlgorithm
pd Example 6
Component --Identifier-- -------Detailed Description----------
PD Disk:32 ST3400755FC PD for cage type DCS2 in cage position 2:0:0 is missing from the firmware
database
pd Suggested Action 6
Check the release notes for mandatory updates and patches to the HPE 3PAR OS version that is
installed and install as needed to support this PD in this Drive Enclosure (cage).

pdch

Displays chunklets state issues
Checks LD connection paths, remote chunklets, and remote disks
FC
degraded old_firmware
Sparing Algorithm is not set
--Value--
:
:
:
:
:
0.0.0.0
:
Unknown
fips_capable
0
0
0
0
85
pdch