PD disk:<pdid> "Degraded States: <showpd -s -degraded>"
PD disk:<pdid> "Failed States: <showpd -s -failed">
PD -- "Sparing algorithm is not set"
PD disk:<pdid> "Disk is experiencing a high level of I/O per second: <iops>"
PD File: <filename> "Folder not found on all Nodes in <folder>"
PD File: <filename> "Folder not found on some Nodes in <folder>"
PD File: <filename> "File not found on all Nodes in <folder>"
PD File: <filename> "File not found on some Nodes in <folder>"
PD Disk:<pdID> "<pdmodel> PD for cage type <cagetype> in cage position <pos> is missing from firmware database"
PD Cage:<cageID> "There must be at least 1 PD with primary path to Node:<nodeID>"
PD Cage:<cageID> "PDs <class/rpm/cap> unbalanced. Primary path: <p_count> on Node:<nodeID>, <c_count> on
Node:<nodeID>"
PD Nodes:<nodelist> "Only <count> <class/rpm/cap> PDs are attached to these nodes; the minimum is <MINDISKCNT>"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> on both ports"
PD pd:<pdID> "PD SAS speed is <speed> instead of <speed> from port <0|1>"
PD disk:<pdWWN> "Unadmitted PD in cage position <CagePos> Type <devType>"
PD cage:<cageID>,mag:<magID> "Magazine has a failed servicemag operation"
PD cage:<cageID>,mag:<magID> "Magazine is being serviced"
PD cage:<cageID>,mag:<magID> "Magazine has an active servicemag operation in progress"
pd Example 1
Component -------------------Summary Description------------------- Qty
PD
PDs that are degraded or failed
Component -Identifier- ---------------Detailed Description-----------------
PD
disk:48
missing_B_port,loop_failure
PD
disk:49
missing_B_port,loop_failure
...
PD
disk:107
pd Suggested Action 1
Both degraded and failed Drives show up in this report. When an FC path to a Drive Enclosure (cage) is
not working, all Drives in the cage have a state of Degraded due to the non-redundant condition. Use
commands such as showpd, showpd -s, showcage, showcage -d.
cli% showpd -degraded -failed
Id CagePos Type Speed(K) State
48 3:0:0
49 3:1:0
...
107 4:9:3
cli% showpd -s -degraded -failed
cli% showcage -d cage3
pd Example 2
82
Troubleshooting
Detailed State:
Detailed State:
Detailed State: failed,notready,missing_A_port
FC
10 degraded
FC
10 degraded
FC
15 failed
----Size(MB)---- ----Ports----
Total
Free A
139520
115200 2:0:2* -----
139520
121344 2:0:2* -----
428800
0 -----
40
B
3:0:1*

Hide quick links: