8.
Locate the failed SFP Transceiver.
To locate the port containing the failed SFP Transceiver, use the Node:Slot:Port position. The port
will have a flashing green Link Status LED and the Port Speed LED will be off.
Removal:
9.
Label the optical cable connected to the failed SFP Transceiver with the port location, and then
disconnect the cable.
10. Remove the SFP Transceiver.
a. Open the retaining clip on the SFP Transceiver.
b. Slide the SFP Transceiver out of the port slot.
Replacement:
11. Install the SFP Transceiver.
a. Open the retaining clip on the SFP Transceiver.
b. Slide the SFP Transceiver into the port slot on the controller node until fully seated.
c. Close the retaining clip.
12. Reconnect the optical cable in the same location recorded on the label.
IMPORTANT:
If an optical cable will not be connected to the SFP Transceiver, install a dust cover.
Verification:
13. Verify that the replacement SFP Transceiver has been successfully installed.
On the port with the replacement SFP Transceiver, verify that the Link Status LED is solid green and
the Port Speed LED is flashing amber.
14. From the SC interface, verify that the State of the component and the storage system are Normal
(green).
15. After the component replacement, initiate Check Health of the storage system.
a. From the SC interface, select Systems.
b. Select Actions > Check health. A scan of the storage system will be run to make sure that there
are no additional issues.
A scan of the storage system will be run to make sure that there are no additional issues.
16. If significant time is left in the maintenance window, end the Maintenance Mode.
a. From the SC interface, select Systems.
b. Select Actions > Set maintenance mode.
c. To end the maintenance window associated with the replacement, click X. The flow of support
information and local notifications of system alerts are again sent to HPE.
17. Follow the return instructions provided with the replacement component.