NOTE:
The error counters shown by shownet and shownet -d cannot be cleared except by rebooting a
controller node. Because checkhealth is comparing network counters with a history log,
checkhealth stops reporting the issue if there is no increase in error in the next log entry.
cli% shownet -d
IP Address: 192.168.56.209
Assigned to nodes: 0123
Connected through node 0
Status: Active
Admin interface on node 0
MAC Address:
RX Packets:
RX Bytes:
RX Errors:
RX Dropped:
RX FIFO Errors:
RX Frame Errors:
RX Multicast:
RX Compressed:
pd
Displays Physical Drives (PDs) with states or conditions that are not optimal:
Checks for failed and degraded PDs
Checks for an imbalance of PD ports, for example, if Port-A is used on more Drives than Port-B
Checks for an Unknown Sparing Algorithm. For example, when it hasn't been set
Checks for Drives experiencing a high number of IOPS
Reports if a servicemag operation is outstanding (servicemag status)
Reports if there are PDs that do not have entries in the firmware DB file
Reports PDs with slow SAS connections
Reports minimum number of PDs in a Drive Enclosure (cage) and behind a node pair
Reports PDs that are not admitted to the system
Format of Possible pd Exception Messages
Netmask 255.255.255.0
00:02:AC:25:04:03
1225109
1089073679
0
0
0
60
0
0
TX Packets:
TX Bytes:
TX Errors:
TX Dropped:
TX FIFO Errors:
TX Collisions:
TX Carrier Errors:
TX Compressed:
550205
568149943
0
0
0
0
0
0
81