Sfp Transceiver Replacement-Mandatory Csr Component - HPE 3PAR StoreServ 7000 Storage Service And Upgrade Manual

Customer edition
Hide thumbs Also See for 3PAR StoreServ 7000 Storage:
Table of Contents

Advertisement

From the SC interface, the Drive ID that you just replaced will be removed from the list, and the
replacement Drive will be assigned a new Drive ID and be in a healthy state. The Schematic view
automatically refreshes.
13. From the SC interface, verify that the State of the component and the storage system are Normal
(green).
14. After the component replacement, initiate Check Health of the storage system.
a. From the SC interface, select Systems.
b. Select Actions > Check health. A scan of the storage system will be run to make sure that there
are no additional issues.
A scan of the storage system will be run to make sure that there are no additional issues.
15. Install the Bezel on the enclosure front.
a. Insert the Bezel into the enclosure right side (1).
b. Press in the release tab (2).
c. Insert the Bezel into the enclosure left side (3).
d. Lock the Bezel (4) (optional).
Figure 12: Installing an HPE 3PAR StoreServ 7000 Storage Bezel
16. Follow the return instructions provided with the replacement component.
SFP Transceiver Replacement—Mandatory CSR
component
An HPE 3PAR StoreServ 7000 Storage Small Form-Factor Pluggable (SFP) Transceiver is a mandatory
Customer Self Repair (CSR) component. An SFP Transceiver is installed in each onboard Fibre Channel
(FC) port and in the ports of Host Adapters.
SFP Transceiver Replacement—Mandatory CSR component
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents