Guidelines For Allocating And Loading Drives - HPE 3PAR StoreServ 7000 Storage Service And Upgrade Manual

Customer edition
Hide thumbs Also See for 3PAR StoreServ 7000 Storage:
Table of Contents

Advertisement

Upgrading to add Drives—SP 4.x on page 35
Upgrading to add Drives—SP 5.x on page 39

Guidelines for allocating and loading Drives

A Drive Pair or Drive Pairs must be installed together and must be of the same capacity, speed, and
type. Never install an uneven number of Drives of one type within a single enclosure.
While making sure to load Drives in pairs of the same Drive type, try to distribute the same number of
Drives and Drive types in all enclosures. An even distribution may not always be possible.
Different Drive types can be loaded next to each other in the same enclosure, but load all the Drives of
one Drive type before loading Drives of a different Drive type.
HPE 3PAR StoreServ 7000 Storage SFF Drive loading guidelines and examples
SFF Drives are loaded starting at bay 0, left to right. The bays are numbered 0 through 23.
Figure 13: HPE 3PAR StoreServ 7000 Storage SFF numbering of Drive bays
Figure 14: HPE 3PAR StoreServ 7000 Storage SFF Drive loading order
This example demonstrates an SFF enclosure loaded correctly with these Drives: two pairs of FC, three
pairs of NL, and two pairs of SSD.
32
Guidelines for allocating and loading Drives
Example of a correct Drive allocation in one SFF enclosure

Hide quick links:

Advertisement

Table of Contents
loading