Digital Swio Submenu; Table 8.3 - Leuze electronic BCL500i Technical Description

Hide thumbs Also See for BCL500i:
Table of Contents

Advertisement

Display and control panel
Digital SWIO
The Digital SWIO submenu is used to configure the 4 switching inputs/outputs of the
BCL 500
i
\ BCL 501

Table 8.3:

Level 3
Sw. input/
output 1
96
i
.

Digital SWIO submenu

Level 4
Level 5
I/O mode
Switching input Inverted
Debounce time
Start-up delay
Pulse duration
Switch-off delay
Function
BCL 500
Selection/configuration option
Description
Input / Output / Passive
Determines the function of switching
input/output 1.
In the case of passive, the connection
is on 0V if the Inverted parameter is
set to OFF , and on +UB if the Inverted
parameter is set to ON.
OFF / ON
OFF = activation of the switching input
function upon high level at the switch-
ing input
ON = activation of the switching input
function upon low level at the switch-
ing input
Value from 0 to 1000
Time in milliseconds for which the
input signal must be present and sta-
ble.
Value from 0 to 65535
Time in milliseconds between the end
of the debounce time and activation of
the function configured below.
Value from 0 to 65535
Minimum activation time in millisec-
onds for the function configured
below.
Value from 0 to 65535
Time in milliseconds for which the
function configured below remains
activated after the switching input sig-
nal is deactivated and the pulse dura-
tion has expired.
No BCL500i function
Rd. gate start/stop
Rd. gate stop
Rd. gate start
Teach reference code
Autoconfig start/stop
The function set here is carried out
after the switching input is activated.
i
i
\ BCL 501
Standard
Input
OFF
5
0
0
0
Reading gate
start/stop
Leuze electronic

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcl501i

Table of Contents