Online Commands; Overview Of Commands And Parameters - Leuze electronic BCL500i Technical Description

Hide thumbs Also See for BCL500i:
Table of Contents

Advertisement

11

Online commands

11.1

Overview of commands and parameters

Online commands can be used to send commands directly to the device for control and
configuration.
For this purpose, the BCL 500
via the serial interface. The commands described can be sent either via the host or the
service interface.
Online commands
With the commands, you can:
• control/decode.
• read/write/copy parameters.
• carry out an automatic configuration.
• teach-in/set reference codes.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialise the device.
Syntax
"Online" commands consist of one or two ASCII characters followed by command parame-
ters.
No separation characters may be entered between the command and the command param-
eter(s). Both small and capitalised letters can be used.
Example:
Command 'CA': autoConfig function
Parameter '+':
Transmitted is:
Notation
Commands, command parameters and returned data are enclosed between single quota-
tion marks ' ' in the text of this manual.
Most online commands are acknowledged by the BCL 500
data returned. For commands that are not acknowledged, command execution can be
observed or monitored directly on the device.
Leuze electronic
i
\ BCL 501
Activation
'CA+'
BCL 500
i
must be connected to a host- or service computer
i
i
\ BCL 501
Online commands
i
i
\ BCL 501
and any requested
123