Commissioning and configuration

10.1.5 Operation as a multiNet plus master

For operation as a multiNet plus master, you must tell the BCL 500
of slaves it is to administer. This is performed using the max. slave number parameter.
Set the max. slave number parameter to the desired value:
• Via webConfig:
Configuration -> Communication -> BUS OUT -> Protocol
• Or, alternatively, via the display
Parameter
Parameter handling
Decoder table
Digital SWIO
o Com
Com
Operating mode
HOST / BUS IN
o BUS OUT
BUS OUT
o multiNet master
multiNet slave
multiNet master
o max. slave number
Max. no. of slaves
1|
<-|0123456789
Standard ----- Unit
You also need to configure the BCL 500
host:
112
save
1
|
|
BCL 500
1
In the Parameter menu, use the
select the Com menu item.
Press the enter button to enter the Com menu.
Use the
buttons to select the BUS OUT menu
item.
Press the enter button to enter the BUS OUT menu.
Use the
buttons to select the
multiNet master menu item.
Press the enter button to enter the
multiNet master menu.
Press the
enter button to enter the menu for set-
ting the maximum number of slaves.
Displayed in the following screen is the preset
number 1, which you can now change. Use the
and
buttons to set the desired number of slaves.
An accidental, incorrect entry can be corrected by
selecting
and then pressing
<-|
Then use the
the set number of slaves by pressing
i
such that it is able to communicate with the primary
i
i
\ BCL 501
i
the maximum number
buttons to
.
buttons to select save and save
Leuze electronic
.

Advertisement