Writing parameter set
Command
Description
Parameter
Leuze electronic
The parameters of the BCL 500
parameter set and permanently stored in memory. There is one param-
eter set in permanent memory and one operating parameter set in vol-
atile memory; in addition, there is a default parameter set (factory
parameter set) for initialisation. This command can be used to edit the
first two parameter sets (in permanent and volatile memory). A check
sum can be used for reliable parameter transfer.
PT<BCC type><PS type><Status><Adr.><P.value adr.>
<P.value adr+1>...[;<Adr.><P.value adr.>][<BCC>]
<BCC type>Check-digit function during transfer,
unit [dimensionless]
'0'
No check digit
'3'
BCC mode 3
<PS type> Memory from which the values are to be read,
unit [dimensionless]
'0'
Parameter values stored in the flash memory
'3'
Operating values stored in RAM
<Status>
Mode of parameter processing, without function here, unit
[dimensionless]
'0'
No reset after parameter change, no further parameters
'1'
No reset after parameter change, additional parameters
follow
'2'
With reset after parameter change, no further parame-
ters
'6'
Set parameters to factory setting, no further parameters
'7'
Set parameters to factory settings, lock all code types;
the code-type setting must follow in the command!
<Adr.>
Relative address of the data within the data set,
'aaaa'
Four-digit, unit [dimensionless]
<P.value> Parameter value of the -bb- parameter stored at this
address. The parameter set data is converted from HEX
format to a 2-byte-ASCII format for transfer.
<BCC>
Check sum calculated as specified under BCC type
i
BCL 500
'PT'
i
\ BCL 501
i
\ BCL 501
Online commands
i
are grouped together in a
137