Requesting parameter data set from BCL
Command
Description
Parameter
Leuze electronic
The parameters of the BCL 500
parameter set and permanently stored in memory. There is one param-
eter set in permanent memory and one operating parameter set in vol-
atile memory; in addition, there is a default parameter set (factory
parameter set) for initialisation. This command can be used to edit the
first two parameter sets (in permanent and volatile memory). A check
sum can be used for reliable parameter transfer.
'PR<BCC type><PS type><Address><Data length>[<BCC>]'
<BCC type>Check-digit function during transfer,
unit [dimensionless]
'0'
Not used
'3'
BCC mode 3
<PS type> Memory from which the values are to be read,
unit [dimensionless]
'0'
Parameter values stored in the flash memory
'1'
Reserved
'2'
Default values
'3'
Operating values in RAM
<Address> Relative address of the data within the data set
'aaaa'
Four-digit, unit [dimensionless]
<Data length> Length of the parameter data to be transferred
'bbbb'
Four-digit, unit [length in bytes]
<BCC>
Check sum calculated as specified under BCC type
i
BCL 500
500i
\ BCL
501i
'PR'
i
\ BCL 501
i
\ BCL 501